ASTM E398 is a standard test technique for determining the rate of water vapour transfer through a flexible barrier material in a dynamic manner and converting the results to commonly used water vapour transmission (WVT) units. The performance of specimens evaluated using this method is expressed in SI units.

    Talk to an Expert
    ASTM E398 WVTR Testing by Dynamic Relative Humidity Measurement

    TRUSTED BY

    • Overview
    • Scope, Applications, and Benefits
    • Test Process
    • Specifications
    • Instrumentation
    • Results and Deliverables

    ASTM E398 WVTR Test Overview

    ASTM E398 is a standardized testing procedure used to determine the Water Vapor Transmission Rate (WVTR), also known as Moisture Vapor Transmission Rate (MVTR), of flexible sheet materials. 

    ASTM E398 uses a dynamic relative humidity measurement, in contrast to conventional “cup” methods that depend on weighing samples over several days. This method is much quicker and is intended to replicate actual storage conditions in which moisture moves from a package into the surrounding environment without being continuously carried away by dry gas.

    Scope, Applications, and Benefits

    Scope

    ASTM E398 outlines procedures for measuring water vapor transmission through sheet materials using a dynamic humidity gradient. It evaluates:

    • Water vapor transmission rate (WVTR)
    • Moisture permeability
    • Barrier performance of materials
    • Environmental resistance

    Applications

    • Evaluation of moisture barrier properties of packaging films and laminates.
    • Testing of construction materials, including membranes, foils, and insulation facings.
    • Performance assessment of polymeric sheets and coated materials.
    • Quality control in the manufacturing of moisture-sensitive products.
    • Research and development of advanced barrier materials.

    Benefits

    • Provides accurate and reproducible measurement of water vapor transmission rate
    • Uses dynamic relative humidity measurement for improved sensitivity and response
    • Suitable for low-permeability and barrier-type sheet materials
    • Enables comparison of moisture barrier performance across materials
    • Supports quality assurance and material development processes

    ASTM E398 WVTR Test Process

    Specimen Preparation

    Cut test specimen to the required size; condition as specified in the standard.

    1

    Instrument Setup

    Set test temperature and establish dynamic relative humidity conditions.

    2

    Specimen Mounting

    Seal the specimen securely between the dry and humid chambers.

    3

    Reporting

    Report WVTR with test temperature, humidity conditions, and specimen details.

    4

    ASTM E398 WVTR Technical Specifications

    ParameterDetails
    Specimen TypeFlexible or semi-rigid sheet materials
    Specimen AreaAs specified by the test cell design
    Relative Humidity GradientControlled from a dry to a humid environment
    Measurement PrincipleChange in relative humidity over time
    Test DurationUntil steady-state WVTR is achieved
    OutputWater Vapor Transmission Rate (WVTR)

    Instrumentation Used

    • Dynamic relative humidity water vapor transmission test chamber
    • Controlled temperature and humidity system
    • High-precision hygrometers or humidity sensors
    • Specimen holder or test cell
    • Data acquisition and analysis system
    • Airflow control system (if required)

    Results and Deliverables

    • Water vapor transmission rate (g/m²·day)
    • Moisture permeability data
    • Barrier performance evaluation
    • Material comparison analysis
    • Compliance reports

    Partnering with Infinita Lab for Optimal Results

    Infinita Lab addresses the most frustrating pain points in the ASTM E398 testing process: complexity, coordination, and confidentiality. Our platform is built for secure, simplified support, allowing engineering and R&D teams to focus on what matters most: innovation. From kickoff to final report, we orchestrate every detail—fast, seamlessly, and behind the scenes.

    Looking for a trusted partner to achieve your research goals? Schedule a meeting with us, send us a request, or call us at (888) 878-3090  to learn more about our services and how we can support you. Request a Quote

    Frequently Asked Questions

    The measurement of WVTR is essential in determining the efficiency of a material used as a vapor barrier. It is also helpful in determining the ability of items such as packaging films, coatings, or membranes to shield products from moisture impacts, which determines product durability and performance in various applications.

    The ASTM E398 test method measures the rate of water vapor passage through a sheet material based on a dynamic relative humidity measurement technique. One chamber of the material has a higher humidity, while a sensitive sensor is placed in the other chamber to monitor moisture transmission.

    The apparatus has several major constituents: the test cell, clamping arrangement, humidification provision, air source, sensor, data collection system, temperature control, and standard calibration films. Together, these components deliver a reliable WVTR measurement under controlled conditions.

    The standard procedure, ASTM E398, is widely applied to flexible barrier materials such as plastic films, coatings, membranes, and packaging. Evaluating the effectiveness of those materials in controlling water vapor transmission finds applications in various fields, from packaging to electronics and, finally, construction.

    The factors include leakage from the test seal, improper calibration of the sensor, and variations in humidity. Hence, efforts should be made to eliminate them to a large extent to allow accurate and reproducible measurements.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / ASTM / ASTM E398 WVTR Testing by Dynamic Relative Humidity Measurement

    Discover more from Infinita Lab

    Subscribe now to keep reading and get access to the full archive.

    Continue reading

    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing