Fourier Transform Infrared Spectroscopy – FTIR
Fourier transform infrared spectroscopy (FTIR) is an optical analytical method used to detect the presence of organic and polymeric substances in solid, liquid, and gaseous samples. By creating an infrared absorption spectrum, it can recognise the chemical connections within a molecule. High-resolution spectral data are concurrently collected over a broad spectral range by an FTIR spectrometer.

TRUSTED BY




Precision-driven testing for dimensional accuracy and compliance
- Overview
- Scope, Applications, and Benefits
- Test Process
- Specifications
- Instrumentation
- Results and Deliverables
Overview
Fourier Transform Infrared Spectroscopy (FTIR) is an analysis technique used for identifying compounds and their molecular structure based on the absorption of infrared radiation at specific wavelengths. The molecules in any given compound will tend to absorb infrared radiation at specific frequencies, which correspond to specific types of chemical bonds.
When the FTIR analysis technique is applied, the sample under analysis will be subjected to infrared radiation, and the absorbed radiation will be recorded in the time domain. This recorded data will then be mathematically transformed into the frequency domain, which is referred to as the spectrum, using the Fourier Transformation method.
The FTIR analysis technique has been widely used for the identification of unknown compounds, tracing contaminants, and understanding the structure of polymers, organic compounds, and complex molecules.

Scope, Applications, and Benefits
Scope
FTIR is also a remarkably versatile technique, allowing us to investigate a wide range of materials and samples. It is a useful technique that can be utilized to identify chemicals and determine the composition of various materials, regardless of their state or composition.
FTIR is usually utilized to investigate various conditions, such as:
– Solids
– Liquids
– Gases
– Organic chemicals
– Inorganic chemicals
– Polymers and plastics
– Coatings and thin films
Most of the investigations are conducted in the mid-infrared region, ranging from 4000 cm⁻¹ to 50 cm⁻¹, with a possibility of entering the near-infrared region depending on the settings of the device.
Applications
- Identification of unknown chemical compounds
- Functional group analysis
- Polymer characterization
- Contamination and impurity detection
- Quality control of materials
- Failure analysis and material verification
- Coating and thin film analysis
Benefits
- Rapid and non-destructive testing method
- Minimal sample preparation required
- High sensitivity for molecular identification
- Applicable to solids, liquids, and gases
- Provides unique molecular fingerprint spectra
- Suitable for complex organic materials and polymers
- Enables fast comparison with spectral databases
Test Process
Sample Preparation
The sample is prepared based on its physical form such as solid, liquid, powder, or film.
1IR Radiation Exposure
The sample is exposed to infrared radiation, and molecular bonds absorb specific IR frequencies.
2Interferogram Collection & Fourier Transformation
The instrument records the signal as an interferogram and converts it into a frequency spectrum using Fourier Transformation.
3Spectral Analysis
The obtained spectrum is compared with reference libraries to identify compounds and functional groups.
4Technical Specifications
| Parameter | Details |
|---|---|
| Spectral Range | Typically 4000 cm⁻¹ to 50 cm⁻¹ |
| Analysis Type | Qualitative and quantitative molecular analysis |
| Sample Types | Solids, liquids, gases, powders, films |
| Output Format | IR spectrum showing % transmission or absorbance vs wavenumber (cm⁻¹) |
| Identification Method | Comparison with reference spectral databases |
Instrumentation Used for Testing
- FTIR spectrometer
- Infrared radiation source
- Michelson interferometer
- Sample holders and accessories
- ATR crystal or transmission cells (depending on technique)
- Detector system
- Computer with spectral database software
- Data processing and analysis software
Results and Deliverables
- FTIR spectrum of the sample
- Identification of functional groups
- Molecular fingerprint analysis
- Compound identification report
- Contamination or impurity detection results
- Spectral matching reports
Why Choose Infinita Lab for FTIR?
Infinita Lab offers comprehensive FTIR testing services, a Comprehensive lab network, project management, confidentiality, and rapid turnaround. Trust Infinita Lab for your material testing needs, Faster test results, cost savings, and reduced administrative workload.
Looking for a trusted partner to achieve your research goals? Schedule a meeting with us, send us a request, or call us at (888) 878-3090 to learn more about our services and how we can support you. Request a Quote
Frequently Asked Questions
It is an analytical technique used to identify and characterize chemical compounds based on their molecular vibrations.
FTIR spectra reveal the composition of solids, liquids, and gases. They are most commonly used to identify unknown materials and confirm production materials.
FTIR works on the absorption principle of an infrared light source on the sample.
FTIR spectrometers have several components that work together to produce a spectrum. The essential elements include a source, sample compartment, interferometer, detector, computer, and accessories.
FTIR spectroscopy has the advantages of dispersive IR spectroscopy: high spectral quality, high data collection speed, easy maintenance and use, and high data reproducibility.
Case Studies
In-depth examination of genuine material testing solutions
Dopant and Ultra-Low Concentration Elemental Analysis Using STEM…
Introduction to STEM-EELS for Elemental Analysis Scanning Transmission Electron Microscopy (STEM) combined with Electron Energy Loss...
Read Case StudyAnalysis of PVC Pipe Degradation Using FTIR Spectroscopy
PVC Pipe in Infrastructure — and Why Degradation Matters Polyvinyl chloride (PVC) pressure pipe is one...
Read Case StudyNano-scale roughness measurement of Si-wafers by Atomic Force…
Nano-scale surface roughness is a critical parameter in fabricated thin-films that are used in optics, solar...
Read Case Study
Request a Quote
Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.
Quick Turnaround and Hasslefree process

Confidentiality Guarantee

Free, No-obligation Consultation

100% Customer Satisfaction