Laser Induced Breakdown Spectroscopy (LIBS)

Laser-induced breakdown spectroscopy (LIBS) uses a highly energetic laser pulse as an excitation source to ablate material from sample surfaces, vaporize them to plasma and then identify elements based on characteristic spectral emissions. This enables identification and removal of trace contaminants. In this case study, the LIBS technique was used for detection of low levels of silicone contaminants in CFRP composites.

Last Updated: January 11th, 2024 First Published :
SANS instrument at neutron source facility analyzing nanostructure of polymer material
  

Laser-induced breakdown spectroscopy (LIBS) uses a highly energetic laser pulse as an excitation source, to optically breakdown, vaporize and convert elements in the sample to plasma state. The amount of sample subjected to breakdown (termed ‘ablation’) and vaporization to plasma, is in the range of nanograms to picograms. The plasma cools, within microseconds and various atoms emit characteristic spectral lines that can identify them. The detector needs to be gated to capture full spectral information within the microseconds duration. The principle is illustrated in Figure 1.

Adhesive bonded fibre-polymer composites are important for applications such as light-weighting of structures and components in the transportation sector. They also find application in consumer goods, industrial and infrastructural applications. Composites can be bonded to each other or to metals or non-metals using adhesives. Adhesive bonds between surfaces require the surfaces to be free from contaminants. Even trace contaminants can reduce bond strength and result in structural failure under load.

Carbon Fibre Reinforced Polymers (CFRP) are an important category of composites, due to their light weight, strength and corrosion resistance. Due to its high sensitivity LIBS can be used to detect ultralow concentrations of contamination on CFRP samples.  

In this case study, the LIBS technique was used for detection of low levels of silicone contaminants in CFRP composites. Sample (30.5 cm × 30.5 cm) CFRP panel surfaces were contaminated in a controlled manner with polydimethylsiloxane (PDMS). The panels were analyzed by LIBS before and after laser ablation, providing information on the ability of LIBS to remove silicone as well as to detect very low levels of silicone.

LIBS ablation was performed using an Nd:YVO4 laser system with pulse energies below 30 μJ, duration about 10 picoseconds, lasing wavelength of 350 nm and frequency about 400 kHz. For contamination studies, wavelengths ranging from 370 nm to 900 nm with a 10 nm step size were used at three incident angles: 65°, 70°, and 75°. From this data, the PDMS layer thickness  was inferred. SEM micrographs of ablation depth of the surface at increasing energy of single pulse laser shots are seen in Figure 2. The craters produced show no melted or redeposited material around the crater border. Above15 μJ, an inner crater starts forming due to the increasing energy and the crater deepens faster than it widens. In contrast to the crater contour, the inner crater has a circular shape. In all the LIBS measurements, the pulses do not interact with the carbon fibres underneath the resin surface layer, as shown in the SEM micrographs.

Case Studies

In-depth examination of genuine material testing solutions

Case Study: Dopant & Ultra-Low Concentration Analysis via…

banner

Case Study: Dopant & Ultra-Low Concentration Analysis via…

Introduction to STEM-EELS for Elemental Analysis Scanning Transmission Electron Microscopy (STEM) combined with Electron Energy Loss...

Read Case Study

Analysis of PVC Pipe Degradation Using FTIR Spectroscopy

Fourier Transform Infrared Spectroscopy (FTIR)

Analysis of PVC Pipe Degradation Using FTIR Spectroscopy

PVC Pipe in Infrastructure — and Why Degradation Matters Polyvinyl chloride (PVC) pressure pipe is one...

Read Case Study

Nano-scale roughness measurement of Si-wafers by Atomic Force…

banner

Nano-scale roughness measurement of Si-wafers by Atomic Force…

Nano-scale surface roughness is a critical parameter in fabricated thin-films that are used in optics, solar...

Read Case Study

Looking for Material Testing?

We have already delivered 20,000+ Material Test results to top companies

    Home / Case Studies / Laser Induced Breakdown Spectroscopy (LIBS)

    Discover more from Infinita Lab

    Subscribe now to keep reading and get access to the full archive.

    Continue reading

    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing