(888) 878-3090
The devices used to apply torque throughout industrial processes undergo routine torque calibration to ensure repeatable precision. To evaluate whether any adjustments are required, the torque calibration test equipment compares the instrument's output torque to the permitted tolerance. Businesses that use torque instruments discover that Infinita lab's torque calibration services help them retain traceability and accurate measurement, which supports the quality of their operations.
A torque transducer, tensiometer, torque sensor, and other devices can all be calibrated at Infinita lab with loads up to 2,000 ft-lbs. It is also common practice to calibrate torque wrenches. The highly qualified personnel at the lab can also preset any torque device. Our service is quick, and the calibration outcomes are consistently correct.
For each item certified, a Calibration Certificate is given out, detailing the torque calibration that was done. The certifications provide thorough calibration results as well as details on NIST traceability, A2LA accreditation to ISO/IEC 17025, and “as received” and “as left” conditions demonstrating calibration modifications.
Many torque instruments, including those below within the ranges indicated, can be calibrated and verified by our experts.
Torque calibration specifications are derived from several sources, such as manufacturer recommendations, ANSI/ASME standards, government regulations, and client requirements.
The calibration of torque sensors, preset screwdrivers, and torque wrenches use a torque system that allows users to choose the best transducer for their instrument’s operating range from a variety of options. Transducers are used to calibrate torque multipliers as well, although two are needed. When the other transducer measures the torque output, the first transducer measures the created torque input.
While calibrating a cable tensiometer, a known cable diameter and a set amount of deadweight attached to the cable are used. To ensure that the instrument is reading correctly, the cable tensiometer is fastened to the cable with the suspended weight. This test is repeated using a variety of cables and loads that are adequate for the calibrating instrument.
Torque wheels, arms, and weights are used to calibrate torque transducers, testers, and clocks. To calculate the torque produced, a known length and weight are used as the basis for this operation.
All instruments log “as received” data depending on specified test points. The calibration process records all modifications as “as left” circumstances. Both are detailed along with the calibration findings on the calibration certificate.
Video 1:Torque Calibration and Torque Measurement Instruments
hello@infinitalab.com
Enter Sample and testing requirementsProvide your contact information
Attach file
Δ
EELS analysis of gate and channel is performed on fin field-effect transistors (finFETs). Scanning transmission electron…
FTIR analysis is used to study the migration and leaching of phthalate plasticizers from p-PVCs. Phthalate…
Nano-scale surface roughness is a critical parameter in fabricated thin-films that are used in optics, solar…
Start Testing
ASTM E572 test method covers the analysis of stainless and alloy steels by Wavelength Dispersive X-ray Fluorescence Spectrometry (WDXRF). It provides rapid, multi-element determinations with sufficient accuracy to assure product quality.
The ASTM D2674 test is a standard test method for the analysis of sulfochromate etch solutions used in the surface preparation of aluminum. The ASTM D2674 standard specifies a method for determining the efficacy of an etchant used to prepare the surface of aluminum alloys for subsequent adhesive bonding.
An immunological method for quantization of Hevea Natural Rubber (HNRL) proteins using rabbit anti-HNRL serum. Rabbits immunized with HNRL proteins react to the majority of the proteins present, and their sera have the capability to detect most if not all the proteins in HNRL.
ASTM G65 measures the resistance of metallic materials to abrasion using the dry sand/rubber wheel apparatus. The quality, durability, and toughness of the sample are determined using this test. Metallic materials are ranked in their resistance to scratching abrasion under a controlled environment.
ASTM E2141 test methods provide accelerated aging and monitoring of the performance of time-dependent electrochromic devices (ECD) integrated in insulating glass units (IGU). This test helps to understand the relative serviceability of electrochromic glazings applied on ECD.
ASTM C724 test method is used in analyzing the quality and ease of maintenance of a ceramic decoration on architectural-type glass. This test method is useful in the acknowledgment of technical standards.
You share material and testing requirements with us
You ship your sample to us or arrange for us to pick it up.
We deliver the test report to your email.
Let’s work together!
Share your testing requirements with us and we will be happy to assist you.
What Material or product do you have?
What analysis do you need?
How many parts or coupons do you have?
How fast do you need the results back?
Do you know the goal of the analysis you need?
Contact Information
Name
E-mail
Contact number
Query
Submit