The devices used to apply torque throughout industrial processes undergo routine torque calibration to ensure repeatable precision. To evaluate whether any adjustments are required, the torque calibration test equipment compares the instrument's output torque to the permitted tolerance. Businesses that use torque instruments discover that Infinita lab's torque calibration services help them retain traceability and accurate measurement, which supports the quality of their operations.


  

Tour of Infinita lab’s Torque Calibration

A torque transducer, tensiometer, torque sensor, and other devices can all be calibrated at Infinita lab with loads up to 2,000 ft-lbs. It is also common practice to calibrate torque wrenches. The highly qualified personnel at the lab can also preset any torque device. Our service is quick, and the calibration outcomes are consistently correct.

For each item certified, a Calibration Certificate is given out, detailing the torque calibration that was done. The certifications provide thorough calibration results as well as details on NIST traceability, A2LA accreditation to ISO/IEC 17025, and “as received” and “as left” conditions demonstrating calibration modifications.

Many torque instruments, including those below within the ranges indicated, can be calibrated and verified by our experts. 

Metrology Capabilities

  • torque measurement
  • Calibration of a cable tensiometer
  • Detroit Pull Tester, 0 to 2000 lbs.
  • Torque Sensor Calibration (2400, 3600, 7200 in-lbf, 200, 300, 600, 1000, and 2000 ft-lbf)
  • 3600, 7200 in-lbf, 300, 600, 1000, and 2000 ft-lbf, and 6500 ft-lbs of torque multiplier
  • Screwdriver Torque Counterclockwise & Clockwise
  • 200 ft-lbf and 2400 in-lbf
  • Torque Transducer Calibration 200, 300, 600, 1000, and 2000 ft-lbf 2400, 3600, and 7200 in-lbf
  • lbf Torque Watch 2400
  • Calibration of Torque Wrenches in Clockwise and Counterclockwise
  • 200, 300, 600, 1000, 1800 ft-lbf, 2400, 3600, and 7200 in-lbf

The Processes Of Torque Calibration

Torque calibration specifications are derived from several sources, such as manufacturer recommendations, ANSI/ASME standards, government regulations, and client requirements.

The calibration of torque sensors, preset screwdrivers, and torque wrenches use a torque system that allows users to choose the best transducer for their instrument’s operating range from a variety of options. Transducers are used to calibrate torque multipliers as well, although two are needed. When the other transducer measures the torque output, the first transducer measures the created torque input.

While calibrating a cable tensiometer, a known cable diameter and a set amount of deadweight attached to the cable are used. To ensure that the instrument is reading correctly, the cable tensiometer is fastened to the cable with the suspended weight. This test is repeated using a variety of cables and loads that are adequate for the calibrating instrument.

Torque wheels, arms, and weights are used to calibrate torque transducers, testers, and clocks. To calculate the torque produced, a known length and weight are used as the basis for this operation.

All instruments log “as received” data depending on specified test points. The calibration process records all modifications as “as left” circumstances. Both are detailed along with the calibration findings on the calibration certificate.

Video 1:Torque Calibration and Torque Measurement Instruments

Need help or have a question?
Case Study In-depth examination of genuine material testing solutions
Dopant and ultra-low concentration elemental analysis using Scanning…

EELS analysis of gate and channel is performed on fin field-effect transistors (finFETs). Scanning transmission electron…

Learn More
Analysis of degradation of PVC pipe using Fourier…

FTIR analysis is used to study the migration and leaching of phthalate plasticizers from p-PVCs. Phthalate…

Learn More
Nano-scale roughness measurement of Si-wafers by Atomic Force…

Nano-scale surface roughness is a critical parameter in fabricated thin-films that are used in optics, solar…

Learn More
See all Case Study

Looking for Material Testing?

We have already delivered 10000+ Material Test results to top companies

    Free Consultation? - Talk to our experts

    (888) 878-3090

    Send us a request

      Process for testing
      •  
        STEP 01

        You share material and testing requirements with us

      •  
        STEP 02

        You ship your sample to us or arrange for us to pick it up.

      •  
        STEP 03

        We deliver the test report to your email.

        Let’s work together!

        Share your testing requirements with us and we will be happy to assist you.

        ddd Just share your testing requirements and leave the rest on us!
        • Quick Turnaround and Hasslefree process
        • Confidentiality Guarantee
        • Free, No-obligation Consultation
        • 100% Customer Satisfaction

          ddd

          Let us combine our capabilities to achieve success!!

            idea icon
            Want to connect with an expert before you leave?