UL 10C: 10c Positive Pressure Fire Door Testing Services

Accredited UL 10C 10c positive pressure fire door testing from Infinita Lab, performed to the exact standard requirements - accurate, reproducible results with full documentation for compliance, R&D, and quality control programs.

    UL 10C: 10c Positive Pressure Fire Door Testing Services

    TRUSTED BY

    Get UL 10C compliant results - request your 10c positive pressure fire door testing quote

    What Is UL 10C 10c Positive Pressure Fire Door?

    UL 10C is used to assess the fire-resistance rating of swinging door assemblies subjected to positive-pressure fire conditions. The test procedure is used to determine whether a door assembly can resist fire passage and remain in place during controlled fire exposure and, if necessary, subsequent hose-stream testing.

    UL 10C fire-resistance rating standard is commonly employed for fire-rated door assemblies in wall openings in buildings. The standard is applicable to swinging door and frame assemblies made from a variety of materials.

    Applications and Benefits of UL 10C 10c Positive Pressure Fire Door Testing

    Scope

    UL 10C evaluates the fire endurance of swinging door assemblies mounted in wall openings under positive pressure conditions. The test assesses whether the assembly can limit fire passage and maintain structural integrity during the specified fire exposure period.

    UL 10C evaluates:
    ● Fire resistance of swinging door assemblies under positive pressure
    ● Integrity of door, frame, and hardware during fire exposure
    ● Resistance to the passage of flames and hot gases
    ● Performance of assemblies installed in wall openings
    ● Response of door assemblies to fire endurance and hose stream exposure

    Applications

    ● Fire-rated swinging door assemblies
    ● Commercial and institutional building doors
    ● Steel, wood, and composite fire door systems
    ● Door frames, glazing, and hardware assemblies
    ● Building code compliance testing
    ● Fire safety evaluation for wall opening protectives

    Benefits

    ● Provides standardized fire resistance evaluation of door assemblies
    ● Supports code compliance for fire-rated openings
    ● Helps assess the integrity of door and frame systems during fire
    ● Assists in selecting door assemblies for fire safety applications
    ● Enables comparison of fire performance between door systems

    Our UL 10C Testing Procedure

    Sample Preparation

    The door assembly is mounted in a representative test wall with the required frame, hardware, and accessories.

    1

    Fire Endurance Exposure

    The mounted assembly is exposed to controlled fire conditions under positive pressure for the specified rating period.

    2

    Hose Stream Application

    After fire exposure, the specimen may be subjected to a hose stream test to assess resistance to impact, erosion, and thermal shock.

    3

    Data Recording & Evaluation

    The assembly is evaluated for integrity, opening protection performance, and compliance with the acceptance criteria.

    4

    UL 10C Test Parameters and Requirements

    ParameterDetails
    Applicable MaterialsSwinging door and frame assemblies of various materials
    Mounting ConditionInstalled in a representative wall opening
    Fire Exposure ConditionPositive pressure fire test
    Post-Fire EvaluationHose stream test where applicable
    Measured OutputsFire endurance and assembly integrity
    • Calibrated fire resistance test furnace with positive pressure control system
    • Pressure differential measurement and monitoring instrumentation
    • Standardized time-temperature fire exposure curve control system
    • Flame and hot gas passage observation and recording equipment
    • Door assembly self-closing and latching performance monitoring system
    • Data acquisition and test reporting system

    Equipment and Instrumentation Used for UL 10C Testing

    What You Receive: Test Report, Data, and Certification

    • Positive pressure fire exposure records, including furnace temperature and pressure differential data
    • Flame and hot gas passage observations throughout the fire resistance test period
    • Door assembly integrity and self-closing performance observations per UL 10C criteria
    • Test compliance result assessed against the defined UL 10C fire resistance rating requirements
    • UL 10C positive pressure fire test report for product approval, building code submissions, and regulatory authority review

    UL 10C 10c Positive Pressure Fire Door FAQs

    UL 10C tests how well door assemblies resist fire when there is positive pressure. It checks if doors, frames, and hardware can stop flames and hot gases from passing through during standard fire tests.

    Positive pressure mimics real fire situations where hot gases flow toward door openings. UL 10C makes sure door assemblies can resist flame spread and prevent hot gas leakage in realistic fire exposure conditions.

    UL 10C tests complete door assemblies. This includes the door leaf, frame, glazing, seals, hinges, latches, and hardware. The goal is to assess their overall fire performance in positive pressure furnace conditions.

    UL 10C is often necessary for fire-rated doors in commercial buildings, hospitals, schools, industrial facilities, and other places where building codes require tested fire door assemblies.

    UL 10C tests how well door assemblies perform in a fire under controlled lab conditions. However, it doesn't fully capture all real fire situations. This includes cases with structural movement, smoke management systems, or unusual installation conditions.

    After a UL 10C fire door test failure, manufacturers should work with UL Solutions engineers to review the test report and identify the cause of noncompliance. The review should examine issues such as door deformation, frame separation, hardware failure, seal performance, or openings developed during fire exposure or the hose-stream test. Based on the findings, manufacturers can propose corrective design changes, such as modifying materials, seals, hardware, or assembly construction, for UL Solutions' engineering review. Once the proposed changes are accepted for evaluation, a revised door assembly can undergo retesting to verify compliance. Manufacturers should also maintain updated drawings, material specifications, and test documentation to support the certification process.

    Why Choose Infinita Lab for 10c Positive Pressure Fire Door Testing

    When your 10c Positive Pressure Fire Door results have to hold up - for compliance, a customer audit, or an engineering decision - UL 10C accuracy and an unbiased third-party report matter more than price. Infinita Lab routes your UL 10C 10c positive pressure fire door testing to ISO/IEC 17025-accredited U.S. partner labs with hands-on method experience, so you get defensible data, transparent reporting, and turnaround times built around your project deadline - not ours.

    brain

    Need UL 10C 10c Positive Pressure Fire Door Testing You Can Rely On?

    Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / Services / UL 10C: 10c Positive Pressure Fire Door Testing Services
    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing