ASTM E814: Firestop Penetration Fire Testing Services

Accredited ASTM E814 firestop penetration fire testing from Infinita Lab, performed to the exact standard requirements - accurate, reproducible results with full documentation for compliance, R&D, and quality control programs.

    Talk to an Expert
    ASTM E814: Firestop Penetration Fire Testing Services

    TRUSTED BY

    Get ASTM E814 compliant results - request your firestop penetration fire testing quote

    • Overview
    • Scope, Applications, and Benefits
    • Test Process
    • Specifications
    • Instrumentation
    • Results and Deliverables

    What Is ASTM E814 Firestop Penetration Fire?

    ASTM E814, titled Standard Test Method for Fire Tests of Penetration Firestop Systems, is the standard used to evaluate the fire-resistance performance of firestop systems: the materials, devices, and assemblies used to seal openings in fire-rated walls and floors where pipes, cables, cable trays, conduits, or ducts pass through. These penetrations are necessary for building mechanical, electrical, and plumbing systems, but if left unprotected, they create a path for fire, smoke, and heat to spread between fire-rated compartments. ASTM E814 provides a standardised, repeatable method for confirming that a specific firestop system, installed around a specific penetrating item configuration, will hold back fire for a defined period.

    At a high level, the test involves building a specimen wall or floor assembly representative of field construction, installing the firestop system around the penetrating item(s) as they would be installed on site, and exposing one face of the assembly to a controlled fire inside a test furnace. The furnace follows a standard time-temperature curve, the same exposure curve referenced in ASTM E119, for a specified duration. Thermocouples on the unexposed side and on the penetrating items monitor temperature rise throughout, while observers watch for flame passage through the firestop. Immediately afterwards, a duplicate specimen undergoes a hose stream test, applying water under pressure to evaluate resistance to the physical impact and thermal shock of fire suppression.

    From these observations, the standard establishes two ratings: the F Rating, based on how long the system prevents flame passage, and the T Rating, based on how long the system limits temperature rise on the unexposed side. Because firestop failures can compromise the fire compartmentation that life-safety and property-protection strategies depend on, ASTM E814 testing is central to code compliance, product listings, and engineering judgments throughout building construction.

    Applications and Benefits of ASTM E814 Firestop Penetration Fire Testing

    Scope

    • Evaluates the performance of penetration firestop systems under a standard time-temperature fire test followed by a hose stream test.
    • Establishes an F Rating, based on flame occurrence on the unexposed surface of the firestop system during the fire exposure period.
    • Establishes a T Rating, based on the temperature rise (and any flame occurrence) recorded on the unexposed side of the firestop system and on the penetrating item.
    • Requires a supporting construction, a fire-rated wall or floor assembly, fabricated to represent the building element the firestop system is intended to protect.
    • Applies to firestop systems installed around actual or representative penetrating items, including pipes, cables, cable trays, conduits, and ducts, whether single penetrations or multiple penetrations through a common opening.
    • Covers a wide range of firestop materials and configurations, including mineral wool, ceramic wool, sealants, caulks, putties, wraps, intumescent materials, and cast-in-place devices.
    • Excludes membrane penetrations evaluated as part of floor-ceiling assemblies tested to ASTM E119 and does not apply to penetrations through load-bearing wall assemblies covered separately by that standard.
    • Uses the same furnace exposure basis (standard time-temperature curve) referenced in ASTM E119 fire tests of building construction and materials.
    • Is closely related to UL 1479, which uses a comparable methodology and adds optional L (air leakage) and W (water leakage) ratings.
    • Supports the development and evaluation of firestop products and systems for building code compliance, third-party product listings, and engineering judgment documentation.

    Applications

    • Qualification testing of penetration firestop products and systems by manufacturers seeking code-compliant listings.
    • Verification testing for electrical, mechanical, and plumbing contractors installing firestop systems in fire-rated wall and floor assemblies.
    • Support for building code compliance and inspection requirements on new construction and renovation projects.
    • Development of engineering judgments for field conditions that fall outside the exact scope of an existing tested system.
    • Product comparison and selection by architects, engineers, and specifiers evaluating firestop systems for a project.
    • Due diligence and documentation for fire-stopping subcontractors and general contractors on life-safety-critical projects.
    • Supplemental data supporting related evaluations such as UL 1479 testing and third-party product certification programs.

    Benefits

    • Provides an independent, standardised basis for confirming that a firestop system performs as intended under real fire conditions.
    • Distinguishes flame-blocking performance (F Rating) from heat-transfer performance (T Rating), giving specifiers the information needed for combustible-material and life-safety applications.
    • Verifies that a firestop system can withstand the physical shock of a hose stream immediately following fire exposure, not just static fire exposure alone.
    • Generates documented, third-party test data that supports code compliance submittals and building inspections.
    • Helps manufacturers and contractors avoid costly field failures, callbacks, or compliance issues tied to unproven firestop configurations.
    • Supports informed product selection among competing firestop materials and system designs.

    Our ASTM E814 Testing Procedure

    Sample Preparation

    Firestop specimens assembled in fire-rated wall or floor assembly per ASTM E 814 requirements.

    1

    Fire Exposure

    Specimens subjected to standardized time-temperature fire curve for defined test duration.

    2

    Hose Stream Test

    Following fire exposure specimens subjected to defined hose stream impact and integrity assessment.

    3

    Post-Exposure Evaluation

    Fire and hose stream performance assessed against ASTM E 814 criteria for test compliance result.

    4

    ASTM E814 Test Parameters and Requirements

    ParameterDetails
    Applicable SystemsCable, conduit, pipe, and mechanical penetration firestop systems in wall and floor assemblies
    Specimen ConfigurationDefined penetrating item and firestop assembly per ASTM E 814 installation requirements
    Fire Exposure CurveStandardized time-temperature fire exposure curve per ASTM E 814 conditions
    Measured ParametersFlame passage, hot gas leakage, temperature transmission, and hose stream integrity
    Measured OutputsF rating, T rating, hose stream integrity observations, and test compliance result
    • Fire Test Furnace – provides the controlled, calibrated fire exposure to the specimen following the standard time-temperature curve.
    • Thermocouples – monitor and record temperature on the unexposed side of the firestop system and on the penetrating items throughout the fire exposure.
    • Hose Stream Test Apparatus – delivers a standardised fire hose stream to the fire-exposed specimen to evaluate physical and thermal shock resistance.
    • Timer / Data Acquisition System – tracks furnace exposure duration and logs thermocouple readings for rating determination and reporting.
    • Specimen Wall/Floor Assembly Construction Materials – gypsum board, concrete, masonry, or other materials used to build the representative fire-rated supporting construction.
    • Firestop Materials and Devices Under Test – mineral wool, sealants, caulks, wraps, intumescent products, or cast-in-place devices installed as the system being evaluated.
    • Furnace Pressure and Temperature Control Instrumentation – maintains the required furnace pressure and conformance to the specified time-temperature exposure curve.

    Equipment and Instrumentation Used for ASTM E814 Testing

    What You Receive: Test Report, Data, and Certification

    • Assigned F Rating and T Rating, expressed in hours, for the tested firestop system and penetrating item configuration.
    • Time-stamped temperature data from all monitored thermocouple locations on the unexposed side and on the penetrating items.
    • Observations and timing of any flame passage through the firestop system during fire exposure.
    • Hose stream test results documenting the specimen’s performance under post-fire physical and thermal shock.
    • A formal test report documenting the assembly design, firestop system installation details, instrumentation, and test results.
    • Supporting documentation suitable for product listings, code compliance submittals, and engineering judgment development.

    ASTM E814 Firestop Penetration Fire FAQs

    ASTM E814 and UL 1479 are equivalent firestop test standards evaluating penetration fire resistance. ASTM is a consensus standard, while UL 1479 is UL’s version. Both measure F and T ratings under similar fire exposure conditions.

    In ASTM E814, the F rating indicates how long a firestop system prevents flame passage. The T rating measures time until the unexposed side temperature rises 325°F above ambient, indicating heat transfer resistance.

    ASTM E814 testing duration depends on the required rating, typically 1 to 4 hours of fire exposure. Including setup, curing, instrumentation, and reporting, the full testing process may take several days to weeks.

    Firestop products used for through-penetrations, such as sealants, collars, wraps, sleeves, and composite systems around pipes, cables, and ducts, require ASTM E814 testing to ensure compliance with fire-resistance-rated wall and floor assemblies.

    The F rating measures resistance to flame passage through a firestop system, while the T rating measures resistance to heat transfer. F focuses on fire containment, whereas T evaluates insulation performance and temperature rise limitation.

    ASTM E814 evaluates penetration firestop systems by exposing them to a standardized time-temperature fire test and hose-stream test. Performance is assessed using F and T ratings, based on flame passage and temperature rise on the unexposed side.

    UL 1479 and ASTM E814 evaluate penetration firestop systems under standardized fire and hose-stream exposures. The tests assess the system's ability to prevent flame passage and limit temperature rise through protected penetrations.

    Why Choose Infinita Lab for Firestop Penetration Fire Testing

    When your Firestop Penetration Fire results have to hold up - for compliance, a customer audit, or an engineering decision - ASTM E814 accuracy and an unbiased third-party report matter more than price. Infinita Lab routes your ASTM E814 firestop penetration fire testing to ISO/IEC 17025-accredited U.S. partner labs with hands-on method experience, so you get defensible data, transparent reporting, and turnaround times built around your project deadline - not ours.

    brain

    Need ASTM E814 Firestop Penetration Fire Testing You Can Rely On?

    Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / services / ASTM E814: Firestop Penetration Fire Testing Services

    Discover more from Infinita Lab

    Subscribe now to keep reading and get access to the full archive.

    Continue reading

    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing