ASTM D7574: Bisphenol A Water LC MS MS Testing Services

Accredited ASTM D7574 bisphenol a water LC MS MS testing from Infinita Lab, performed to the exact standard requirements - accurate, reproducible results with full documentation for compliance, R&D, and quality control programs.

    Talk to an Expert
    ASTM D7574: Bisphenol A Water LC MS MS Testing Services

    TRUSTED BY

    Get ASTM D7574 compliant results - request your bisphenol a water LC MS MS testing quote

    • Overview
    • Scope, Applications, and Benefits
    • Test Process
    • Specifications
    • Instrumentation
    • Results and Deliverables

    What Is ASTM D7574 Bisphenol A Water LC MS MS?

    ASTM D7574-23, “Standard Test Method for Determination of Bisphenol A in Environmental Waters by Liquid Chromatography/Tandem Mass Spectrometry,” is the current active edition. ASTM Committee D19 on Water and Environmental Technology maintains it, and it covers identifying and quantifying bisphenol A (BPA) in aqueous environmental samples. The workflow runs in three stages. First, solid-phase extraction (SPE) isolates and concentrates BPA from the water matrix. Then liquid chromatography (LC) separates the analyte from co-extracted interferences. Finally, tandem mass spectrometric (MS/MS) detection, run in multiple reaction monitoring (MRM) mode, confirms identity and measures concentration. Pair chromatographic separation with MS/MS selectivity, and you get both qualitative confirmation and quantitative results from a single run. That combination is what makes the method valuable for trace-level organic contaminant testing.

    Validated scope covers surface water, plus secondary and tertiary effluent from publicly owned treatment works (POTW). It hasn’t been validated for saltwater or solid/sediment matrices, so laboratories keep it within these aqueous environmental contexts. Detection limits and reporting ranges come from documented calibration and statistical procedures, which give laboratories a defensible, standardized basis for reporting low-level BPA concentrations. BPA shows up widely in polycarbonate plastics and epoxy resins, and it reaches waterways through pathways such as landfill leachate and wastewater treatment plant discharge. Because of that, D7574 gives environmental and regulatory testing programs a nationally recognized, repeatable method for tracking the compound across the water environment. It supports consistent, comparable data across laboratories and across successive editions of the standard since its original publication.

    Applications and Benefits of ASTM D7574 Bisphenol A Water LC MS MS Testing

    Scope

    ASTM D7574 evaluates:

    • Lays out a validated procedure for identifying and quantifying bisphenol A (BPA) in environmental water matrices, both qualitatively and quantitatively.
    • Solid-phase extraction (SPE) is the required technique for isolating and concentrating BPA from aqueous samples before instrumental analysis.
    • Liquid chromatographic separation conditions resolve BPA from co-extracted matrix compounds ahead of detection.
    • Detection runs by tandem mass spectrometry (MS/MS) in multiple reaction monitoring (MRM) mode for selective, sensitive confirmation of the analyte.
    • Surface water counts as a validated matrix: rivers, lakes, streams.
    • Also applies to secondary and tertiary publicly owned treatment works (POTW) effluent.
    • Saltwater and solid or sediment matrices are excluded; they sit outside the method’s currently validated scope.
    • Calibration standards, internal standard use, and quality control criteria get guidance here, supporting defensible, reproducible results.
    • Method detection limits (MDLs) and reporting ranges are determined through recognized statistical approaches.
    • Jurisdiction sits with ASTM Committee D19 on Water and Environmental Technology, part of broader water-testing standardization efforts.

    Applications

    • Environmental monitoring programs track BPA contamination in surface waters and receiving streams.
    • Wastewater treatment plants use it to check BPA levels in secondary and tertiary discharge.
    • Endocrine-disrupting compound (EDC) screening studies look at BPA occurrence in aquatic environments.
    • Regulatory and permit-related water quality programs need a standardized analytical methodology, and this fits.
    • Researchers examine BPA sources, fate, and occurrence in environmental water systems.
    • Site assessments near facilities tied to polycarbonate plastics or epoxy resin use, or near landfill leachate pathways.
    • Exposure and risk-assessment studies tied to aquatic ecosystems and wildlife draw on it too.

    Benefits

    • Trace-level sensitivity means low concentrations of BPA in environmental waters don’t slip past detection.
    • SPE, LC, and MS/MS work together for high selectivity, cutting interference from complex water matrices.
    • One analytical procedure yields both qualitative confirmation and quantitative concentration data.
    • Multiple reaction monitoring adds confidence to analyte identification and cuts down false positives.
    • It’s a nationally recognized, standardized methodology, which helps with data defensibility and comparing results across labs.
    • Decision-making around environmental monitoring, compliance, and research gets easier with this kind of data.

    Our ASTM D7574 Testing Procedure

    Sample pH Adjustment & SPE

    The sample is adjusted to pH 2 and passed through a SPE cartridge to isolate BPA.

    1

    Solvent Extraction

    BPA is extracted using methyl tert-butyl ether.

    2

    Solvent Exchange & Volume Adjustment

    The extract is exchanged into methanol, concentrated, and the final volume adjusted.

    3

    Instrumental Analysis & Identification

    LC-MS/MS analysis of the sample identifies BPA.

    4

    ASTM D7574 Test Parameters and Requirements

    ParameterDetails
    Applicable SamplesWater samples
    Sample Volume250 mL
    Extraction pH2
    Final Extract Volume1 mL
    Solvent UsedMethyl tert-butyl ether, methanol
    Detection TechniqueLC-MS/MS
    • Liquid Chromatograph (LC) – Separates BPA from co-extracted matrix compounds before mass spectrometric detection.
    • Tandem Mass Spectrometer (MS/MS) – Delivers selective, sensitive detection and quantification through multiple reaction monitoring.
    • Solid Phase Extraction (SPE) System – Isolates and concentrates BPA from aqueous sample matrices ahead of instrumental analysis.
    • Analytical Balance – Used for accurate preparation of calibration standards, reagents, and reference materials.
    • Nitrogen Evaporator/Concentrator – Brings extract volume down to what’s needed for instrumental analysis.
    • Autosampler – Keeps sample introduction consistent and reproducible across analytical batches.
    • Certified Reference Standards – Generate calibration curves and verify ongoing method performance and quality control.

    Equipment and Instrumentation Used for ASTM D7574 Testing

    What You Receive: Test Report, Data, and Certification

    • Quantitative BPA concentration results, one per submitted water sample.
    • MDL and reporting limit documentation tied to the analytical batch.
    • A quality control summary: method blank, spike, and surrogate recovery data included.
    • Chain-of-custody records, so sample traceability holds from collection through reporting.
    • A full laboratory report, formatted for regulatory submission, internal review, or client files.
    • Technical consultation to help interpret results and what they mean for compliance or monitoring.

    ASTM D7574 Bisphenol A Water LC MS MS FAQs

    ASTM D7574 determines Bisphenol A (BPA) qualitatively and quantitatively in environmental water samples. The method uses solid-phase extraction (SPE), followed by liquid chromatography and tandem mass spectrometry (LC-MS/MS) with multiple reaction monitoring (MRM).

    ASTM D7574 has been investigated for surface water and secondary and tertiary wastewater treatment effluents. The method has not been investigated for saltwater or solid sample matrices, so applicability should be confirmed for samples outside the validated scope.

    Water samples undergo solid-phase extraction to isolate BPA, followed by separation using liquid chromatography. BPA is then identified and quantified using tandem mass spectrometry (MS/MS) with multiple reaction monitoring.

    ASTM D7574 specifies a method detection limit (MDL) and reporting limit (RL) for BPA. The applicable detection and reporting levels should be confirmed from the current method and laboratory validation data before testing, particularly for trace-level environmental monitoring.

    BPA can enter environmental waters through sources such as industrial discharges, wastewater treatment effluents, landfill leachate, and degradation of polycarbonate plastics and epoxy resins. ASTM D7574 provides a sensitive LC-MS/MS approach for monitoring BPA in applicable water matrices and supporting environmental assessment and compliance programs.

    Why Choose Infinita Lab for Bisphenol A Water LC MS MS Testing

    When your Bisphenol A Water LC MS MS results have to hold up - for compliance, a customer audit, or an engineering decision - ASTM D7574 accuracy and an unbiased third-party report matter more than price. Infinita Lab routes your ASTM D7574 bisphenol a water LC MS MS testing to ISO/IEC 17025-accredited U.S. partner labs with hands-on method experience, so you get defensible data, transparent reporting, and turnaround times built around your project deadline - not ours.

    brain

    Need ASTM D7574 Bisphenol A Water LC MS MS Testing You Can Rely On?

    Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / services / ASTM D7574: Bisphenol A Water LC MS MS Testing Services

    Discover more from Infinita Lab

    Subscribe now to keep reading and get access to the full archive.

    Continue reading

    ×