ASTM A598 Magnetic Properties Testing for Magnetic Amplifier Cores
ASTM A 598 describes the standard method for determining the magnetic performance of fully processed cores for magnetic amplifier application. This test is conducted at excitation frequencies of 60,400,1600 Hz or higher.

TRUSTED BY




Precision-driven testing for dimensional accuracy and compliance
- Overview
- Scope, Applications, and Benefits
- Test Process
- Specifications
- Instrumentation
- Results and Deliverables
Overview
ASTM A598 is a standardized procedure to verify the magnetic properties of magnetic amplifier cores. This procedure evaluates the performance of the materials used to make the cores by measuring the magnetic properties such as permeability, coercive force, and flux density under magnetization conditions.
The testing procedure is significant to evaluate the suitability of the magnetic materials to be used in magnetic amplifiers and associated electronic components. The measurement of the magnetic properties is important to ensure the reliable performance of the components used in power control circuits, transformers, etc.

Scope, Applications, and Benefits
Scope
The ASTM A598 code is for determining the way to test the magnetic properties of magnetic amplifier cores, toroidal cores, and other ferromagnetic materials. The test helps to determine the way the cores would react to alternating or direct magnetic fields. The test is done in a controlled environment to determine their suitability for certain applications.
The test results provide the following data:
– Magnetic permeability of the material used for the core
– The coercive force required to demagnetise the material
– The density of the flux produced within the material
– The way the material would be magnetised by an external magnetic field
Applications
- Quality control of magnetic core manufacturing
- Evaluation of ferromagnetic materials
- Design verification of magnetic amplifiers
- Electrical and electronic component testing
- Power control equipment manufacturing
- Transformer and inductive component production
- Research and development of magnetic materials
- Performance testing of control circuit components
Benefits
- Ensures reliable magnetic performance of amplifier cores
- Provides standardized magnetic characterization
- Supports accurate material selection for electronic components
- Improves performance of magnetic control systems
- Detects inconsistencies in magnetic core materials
- Enhances reliability of transformers and inductors
- Supports product development and quality assurance
Test Process
Specimen Preparation
The magnetic core is prepared and fitted with primary and secondary windings.
1Magnetizing Circuit Setup
A magnetizing current is applied to generate a controlled magnetic field in the core.
2Magnetic Flux Measurement
Changes in magnetic flux induce voltage in the secondary winding, which is measured.
3Data Interpretation
Magnetic properties such as permeability, coercive force, and flux density are calculated.
4Technical Specifications
| Parameter | Details |
|---|---|
| Applicable Materials | Magnetic amplifier cores and ferromagnetic core materials |
| Specimen Configuration | Toroidal or core-shaped magnetic specimens with windings |
| Measured Properties | Permeability, coercive force, magnetic flux density |
| Magnetization Type | Controlled alternating or direct magnetic field |
| Output Units | Magnetic field strength, flux density, and permeability values |
Instrumentation Used for Testing
- Magnetising power supply
- Primary and secondary coil windings
- Flux measuring instruments
- Ballistic galvanometer or fluxmeter
- Magnetic field measurement equipment
- Signal detection system
- Precision electrical measurement instruments
- Data acquisition and analysis software
Results and Deliverables
- Magnetic permeability values
- Coercive force measurement
- Magnetic flux density characteristics
- Magnetisation curve analysis
- Magnetic performance evaluation reports
- Reports
Partnering with Infinita Lab for Optimal Results
Infinita Lab addresses the most frustrating pain points in the ASTM A598 testing process: complexity, coordination, and confidentiality. Our platform is built for secure, simplified support, allowing engineering and R&D teams to focus on what matters most: innovation. From kickoff to final report, we orchestrate every detail—fast, seamlessly, and behind the scenes.
Looking for a trusted partner to achieve your research goals? Schedule a meeting with us, send us a request, or call us at (888) 878-3090 to learn more about our services and how we can support you. Request a Quote
Frequently Asked Questions
ASTM A598 is used to evaluate the magnetic properties of magnetic amplifier cores. It measures parameters such as magnetic permeability, coercive force, and flux density to determine how effectively a magnetic core performs in electronic and power control applications.
This test is applicable to ferromagnetic materials used in magnetic amplifier cores, including toroidal magnetic cores and other core shapes used in transformers, inductors, and electronic control devices.
Testing ensures that magnetic cores have the required magnetic characteristics for stable performance in electrical circuits. It helps maintain efficiency, reliability, and consistent operation in power control and electronic systems.
The test typically measures magnetic permeability, coercive force, magnetic flux density, and overall magnetization characteristics of the core material.
The specimen is usually a magnetic core fitted with primary and secondary windings that allow controlled magnetization and measurement of induced magnetic flux.

Request a Quote
Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.
Quick Turnaround and Hasslefree process

Confidentiality Guarantee

Free, No-obligation Consultation

100% Customer Satisfaction