What Is ASTM E398 WVTR Dynamic Relative Humidity?
ASTM E398 is a standardized testing procedure used to determine the Water Vapor Transmission Rate (WVTR), also known as Moisture Vapor Transmission Rate (MVTR), of flexible sheet materials.
ASTM E398 uses a dynamic relative humidity measurement, in contrast to conventional “cup” methods that depend on weighing samples over several days. This method is much quicker and is intended to replicate actual storage conditions in which moisture moves from a package into the surrounding environment without being continuously carried away by dry gas.
Applications and Benefits of ASTM E398 WVTR Dynamic Relative Humidity Testing
Scope
ASTM E398 outlines procedures for measuring water vapor transmission through sheet materials using a dynamic humidity gradient. It evaluates:
- Water vapor transmission rate (WVTR)
- Moisture permeability
- Barrier performance of materials
- Environmental resistance
Applications
- Evaluation of moisture barrier properties of packaging films and laminates.
- Testing of construction materials, including membranes, foils, and insulation facings.
- Performance assessment of polymeric sheets and coated materials.
- Quality control in the manufacturing of moisture-sensitive products.
- Research and development of advanced barrier materials.
Benefits
- Provides accurate and reproducible measurement of water vapor transmission rate
- Uses dynamic relative humidity measurement for improved sensitivity and response
- Suitable for low-permeability and barrier-type sheet materials
- Enables comparison of moisture barrier performance across materials
- Supports quality assurance and material development processes
Our ASTM E398 Testing Procedure
Specimen Preparation
Cut test specimen to the required size; condition as specified in the standard.
1Instrument Setup
Set test temperature and establish dynamic relative humidity conditions.
2Specimen Mounting
Seal the specimen securely between the dry and humid chambers.
3Reporting
Report WVTR with test temperature, humidity conditions, and specimen details.
4ASTM E398 Test Parameters and Requirements
| Parameter | Details |
|---|---|
| Specimen Type | Flexible or semi-rigid sheet materials |
| Specimen Area | As specified by the test cell design |
| Relative Humidity Gradient | Controlled from a dry to a humid environment |
| Measurement Principle | Change in relative humidity over time |
| Test Duration | Until steady-state WVTR is achieved |
| Output | Water Vapor Transmission Rate (WVTR) |
- Dynamic relative humidity water vapor transmission test chamber
- Controlled temperature and humidity system
- High-precision hygrometers or humidity sensors
- Specimen holder or test cell
- Data acquisition and analysis system
- Airflow control system (if required)
Equipment and Instrumentation Used for ASTM E398 Testing
What You Receive: Test Report, Data, and Certification
- Water vapor transmission rate (g/m²·day)
- Moisture permeability data
- Barrier performance evaluation
- Material comparison analysis
- Compliance reports
ASTM E398 WVTR Dynamic Relative Humidity FAQs
The measurement of WVTR is essential in determining the efficiency of a material used as a vapor barrier. It is also helpful in determining the ability of items such as packaging films, coatings, or membranes to shield products from moisture impacts, which determines product durability and performance in various applications.
The ASTM E398 test method measures the rate of water vapor passage through a sheet material based on a dynamic relative humidity measurement technique. One chamber of the material has a higher humidity, while a sensitive sensor is placed in the other chamber to monitor moisture transmission.
The apparatus has several major constituents: the test cell, clamping arrangement, humidification provision, air source, sensor, data collection system, temperature control, and standard calibration films. Together, these components deliver a reliable WVTR measurement under controlled conditions.
The standard procedure, ASTM E398, is widely applied to flexible barrier materials such as plastic films, coatings, membranes, and packaging. Evaluating the effectiveness of those materials in controlling water vapor transmission finds applications in various fields, from packaging to electronics and, finally, construction.
The factors include leakage from the test seal, improper calibration of the sensor, and variations in humidity. Hence, efforts should be made to eliminate them to a large extent to allow accurate and reproducible measurements.
A water vapor transmission rate (WVTR) test measures the amount of water vapor that passes through a material over a specified period. A film or packaging specimen is mounted between environments with different humidity levels, creating a vapor pressure gradient. The moisture passing through the specimen is measured and used to calculate WVTR, typically expressed in g/m²/day.
Water vapor transmission rate testing evaluates the moisture barrier performance of films, coatings, and packaging materials. The specimen is exposed to controlled temperature and humidity conditions, and the water vapor passing through it is measured using a gravimetric or instrumental method. Results help compare barrier properties and determine material suitability for moisture-sensitive products.
A water vapour transmission test measures how readily moisture passes through a material under controlled temperature and humidity conditions. The specimen separates environments with different water vapor pressures, and the transmitted moisture is measured by tracking weight changes or using a sensor-based instrument. Results are reported as WVTR, commonly in g/m²/day, to assess moisture barrier performance in packaging, films, and building materials.
Why Choose Infinita Lab for WVTR Dynamic Relative Humidity Testing
When your WVTR Dynamic Relative Humidity results have to hold up - for compliance, a customer audit, or an engineering decision - ASTM E398 accuracy and an unbiased third-party report matter more than price. Infinita Lab routes your ASTM E398 WVTR dynamic relative humidity testing to ISO/IEC 17025-accredited U.S. partner labs with hands-on method experience, so you get defensible data, transparent reporting, and turnaround times built around your project deadline - not ours.
Need ASTM E398 WVTR Dynamic Relative Humidity Testing You Can Rely On?
Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.