ASTM D7349: Roofing Fastener Seal Capability Testing Services
The capability of asphalt-based roofing and waterproofing materials to seal around fasteners can be determined using the standard test method in ASTM D7349. This method can determine the penetration and prevent transmission of liquid water through the material under defined conditions.

TRUSTED BY




Get ASTM D7349 compliant results — request your roofing fastener seal capability testing quote
- Overview
- Scope, Applications, and Benefits
- Test Process
- Specifications
- Instrumentation
- Results and Deliverables
What Is ASTM D7349 Roofing Fastener Seal Capability?
ASTM D7349 is a standardized test method used to evaluate the sealing performance of roofing and waterproofing materials around fasteners.
This technique provides a consistent, reliable method for assessing water penetration resistance at fastener locations, which are crucial points for potential leaks in waterproofing and roofing systems. Additionally, ASTM D7349 is intended to be used as a standardised performance evaluation technique in product specifications developed by ASTM or other consensus bodies.
Applications and Benefits of ASTM D7349 Roofing Fastener Seal Capability Testing
Scope
ASTM D7349 evaluates:
- Sealability of roofing materials around fasteners
- Resistance to water penetration at fastener points
- Performance of waterproofing membranes
- Integrity of fastening systems under static water exposure
The method applies to roofing and waterproofing products installed using mechanical fasteners.
Applications
- Commercial roofing systems
- Residential roofing materials
- Waterproofing membranes
- Building envelope systems
- Construction material qualification
- Product certification
- Quality control testing
- Research and development
Benefits
- Provides standardized seal ability assessment
- Identifies leakage risk at fastener locations
- Supports product comparison
- Improves roofing system reliability
- Assists in product development
- Ensures compliance with industry standards
- Enhances waterproofing performance
Our ASTM D7349 Testing Procedure
Test Assembly Preparation
Roofing or waterproofing material is fastened to the substrate using a standard fastener.
1Water Column Setup & Conditioning
Assembly is placed on a water-filled container and conditioned at 4 ± 2 °C.
2Exposure Period & Removal
The specimen remains underwater for 72 hours, then is carefully removed.
3Inspection & Pass/Fail Evaluation
All areas are inspected for water presence, and results are classified as pass or fail.
4ASTM D7349 Test Parameters and Requirements
| Parameter | Details |
|---|---|
| Applicable Materials | Roofing and waterproofing membranes |
| Water Depth | 125 ± 6 mm (5 ± 0.25 in) |
| Test Temperature | 4 ± 2 °C (39.2 ± 3.6 °F) |
| Test Duration | 72 ± 0.25 hours |
| Output Units | SI and inch-pound |
- Water column container
- 4 L (1 gallon) bottom can
- Temperature-controlled chamber
- Specimen roller (11.8 kg)
- Fasteners and substrate panels
- Measuring instruments
- Absorbent blotting materials
Equipment and Instrumentation Used for ASTM D7349 Testing
What You Receive: Test Report, Data, and Certification
- Pass/fail assessment
- Visual inspection records
- Photographic documentation
- Leakage evaluation reports
ASTM D7349 Roofing Fastener Seal Capability FAQs
ASTM D7349 determines the capability of an asphalt-based roofing or waterproofing material to seal around a fastener penetration and prevent liquid water from passing through the material under specified test conditions.
The method is intended for asphalt-based roofing and waterproofing materials that are penetrated by fasteners during installation. It can be used for product specifications and comparative evaluation of sealing performance.
Fastener penetrations can create potential pathways for water migration. Testing helps determine whether the material can limit water movement at the interface between the fastener and the roofing or waterproofing material, supporting evaluation of water-tightness in installed systems.
No. ASTM D7349 is a qualitative test method. It evaluates whether liquid water transmission occurs at the fastener penetration under the defined test conditions rather than providing a numerical water-transmission rate.
Yes. The standard does not prohibit testing materials after conditioning intended to simulate environmental stresses and strains. This can be useful when evaluating whether fastener-sealing capability is maintained after specified conditioning procedures.
Why Choose Infinita Lab for Roofing Fastener Seal Capability Testing
At the core of this breadth is our network of 2,000+ accredited laboratories across the USA, offering access to over 10,000 testing methods and analytical services. From advanced materials characterization (SEM, TEM, RBS, XPS) to mechanical, chemical, environmental, biological, and standardized ASTM/ISO-compliant testing, we deliver unmatched flexibility, specialization, and scale. You are never limited by geography, facility, or methodology — Infinita Lab connects you to the right expertise and testing solution, every time.
Need ASTM D7349 Roofing Fastener Seal Capability Testing You Can Rely On?
Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

Request a Quote
Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.
Quick Turnaround and Hasslefree process

Confidentiality Guarantee

Free, No-obligation Consultation

100% Customer Satisfaction

















