ASTM D3335: Paint Lead Cadmium Cobalt Aas Testing Services
ASTM D3335 covers the assessment of lead concentrations ranging from 0.01 to 5%, cadmium concentrations ranging from 50 to 150 ppm (mg/kg), and cobalt concentrations ranging from 50 to 2000 ppm (mg/kg) in the nonvolatile fraction of liquid coatings or dried films. The SI units are to be taken as standard.

TRUSTED BY




Get ASTM D3335 compliant results — request your paint lead cadmium cobalt aas testing quote
- Overview
- Scope, Applications, and Benefits
- Test Process
- Specifications
- Instrumentation
- Results and Deliverables
What Is ASTM D3335 Paint Lead Cadmium Cobalt Aas?
ASTM D3335 determines low concentrations of lead, cadmium, and cobalt in paint using atomic absorption spectroscopy (AAS). The method involves digesting the paint sample and analyzing the metal content with high sensitivity to ensure accurate quantification of trace elements.
This test is essential for evaluating toxic metal content in coatings and ensuring compliance with safety and environmental regulations. It helps manufacturers control hazardous substances, protect user health, and maintain product quality in coatings and paint formulations.
Applications and Benefits of ASTM D3335 Paint Lead Cadmium Cobalt Aas Testing
Scope
ASTM D3335 defines a procedure for measuring trace levels of lead, cadmium, and cobalt in paint films using atomic absorption spectroscopy. It provides reliable data for regulatory compliance and material safety evaluation.
- Applicable to liquid paints and dried paint films
- Determines trace concentrations of Pb, Cd, and Co
- Uses atomic absorption spectroscopy (AAS) technique
- Involves sample digestion prior to analysis
- Suitable for quality control and compliance testing
- Supports environmental and safety assessments
- Enables comparison of metal content across samples
Applications
- Paint and coating analysis
- Regulatory compliance testing
- Environmental and safety assessments
- Product formulation control
- Industrial coating evaluation
Benefits
- Detects trace levels of hazardous metals
- Ensures compliance with safety regulations
- Provides accurate and sensitive analysis
- Supports safer product development
- Enhances environmental responsibility
Our ASTM D3335 Testing Procedure
Sample Preparation
Paint sample is digested using appropriate acids to extract metals.
1Instrument Calibration
AAS instrument is calibrated with standard metal solutions.
2Measurement
Sample solution is analyzed to determine metal concentrations.
3Result Calculation
Concentrations of Pb, Cd, and Co are calculated and reported.
4ASTM D3335 Test Parameters and Requirements
| Parameter | Details |
|---|---|
| Material Type | Paints and coating films |
| Elements | Lead (Pb), Cadmium (Cd), Cobalt (Co) |
| Detection Range | Low ppm levels |
| Measurement Unit | mg/kg or ppm |
| Instrument Type | Flame or graphite furnace AAS |
- Atomic absorption spectrophotometer (AAS)
- Sample digestion system (hot plate or microwave digester)
- Analytical balance
- Volumetric glassware
- Standard calibration solutions
Equipment and Instrumentation Used for ASTM D3335 Testing
What You Receive: Test Report, Data, and Certification
- Concentration of Pb, Cd, and Co (ppm or mg/kg)
- Test conditions and calibration details
- Sample identification and preparation method
- Detection limits and observations
- Compliance statement with ASTM D3335
ASTM D3335 Paint Lead Cadmium Cobalt Aas FAQs
ASTM D3335 is used to determine low concentrations of lead, cadmium, and cobalt in paint. It ensures accurate measurement of toxic metals and helps manufacturers comply with safety and environmental regulations.
These metals are hazardous and can pose health and environmental risks. Testing ensures their levels are within permissible limits, protecting users and ensuring regulatory compliance.
Digestion breaks down the paint matrix and releases metals into solution, enabling accurate measurement using AAS.
It helps limit the release of hazardous metals into the environment, ensuring paints and coatings meet environmental safety standards.
Lead is toxic and can cause serious health issues, especially in children. Regulations limit its use to ensure safety.
Why Choose Infinita Lab for Paint Lead Cadmium Cobalt Aas Testing?
At the core of this breadth is our network of 2,000+ accredited laboratories across the USA, offering access to over 10,000 testing methods and analytical services. From advanced materials characterization (SEM, TEM, RBS, XPS) to mechanical, chemical, environmental, biological, and standardized ASTM/ISO-compliant testing, we deliver unmatched flexibility, specialization, and scale. You are never limited by geography, facility, or methodology — Infinita Lab connects you to the right expertise and testing solution, every time.
Need ASTM D3335 Paint Lead Cadmium Cobalt Aas Testing You Can Rely On?
Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

Request a Quote
Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.
Quick Turnaround and Hasslefree process

Confidentiality Guarantee

Free, No-obligation Consultation

100% Customer Satisfaction