ASTM D1921: Plastic Material Particle Size Sieve Analysis Testing Services

ASTM D1921 test method deals with the particle size of plastic materials in the powdered, granular, or pelletized forms. It utilizes dry sieving, with a lower limit of measurement to be 38 µm. Multiple and specific sieves are selected for test methods A and B, and the distribution of the particle diameter and size are determined. SI units are considered to be standard.

    Talk to an Expert
    ASTM D1921: Plastic Material Particle Size Sieve Analysis Testing Services

    TRUSTED BY

    Get ASTM D1921 compliant results — request your plastic material particle size sieve analysis testing quote

    • Overview
    • Scope, Applications, and Benefits
    • Test Process
    • Specifications
    • Instrumentation
    • Results and Deliverables

    What Is ASTM D1921 Plastic Material Particle Size Sieve Analysis?

    ASTM D1921 establishes a standardized method for determining the particle size distribution of plastic materials in granular or powdered form using sieve analysis. Understanding particle size is fundamental to predicting how a plastic material will process, flow, and perform in end-use applications.

    The test involves passing a sample of plastic material through a series of calibrated sieves with progressively smaller openings. The weight retained on each sieve is measured and expressed as a percentage of the total sample weight. This data is used to generate a particle size distribution profile, which helps manufacturers maintain consistency in raw materials and finished products.

    ASTM D1921 provides two procedures: Procedure A for coarse particles and Procedure B for fine particles, making it applicable across a wide range of granule sizes used in plastic processing.

    Applications and Benefits of ASTM D1921 Plastic Material Particle Size Sieve Analysis Testing

    Scope

    ASTM D1921 evaluates:

    • Particle size distribution of plastic granules and powders
    • Percentage of material retained at each sieve interval
    • Uniformity and consistency of plastic raw materials
    • Conformance of received materials to purchase specifications
    • Fine particle content (dust) in granular materials
    • Oversized particle content in powdered materials

    Applications

    • Plastic resin quality control
    • Raw material incoming inspection
    • Powder coating materials
    • Rotational molding feedstocks
    • Compounding and blending operations
    • Recycled plastic material characterization
    • Research and development

    Benefits

    • Ensures raw material consistency
    • Supports process optimization
    • Reduces molding defects caused by non-uniform particle size
    • Enables supplier qualification
    • Provides a compliance report
    • Improves flow and packing characteristics in processing

    Our ASTM D1921 Testing Procedure

    Sample Preparation

    A representative sample is dried and weighed to the specified mass.

    1

    Sieve Stack Assembly

    Sieves are arranged from largest to smallest opening and placed on a mechanical shaker.

    2

    Sieving

    The sample is placed on the top sieve and shaken for the prescribed duration.

    3

    Weighing & Calculation

    Material retained on each sieve is weighed, and percent retained/passing is calculated.

    4

    ASTM D1921 Test Parameters and Requirements

    ParameterDetails
    ProceduresProcedure A (coarse), Procedure B (fine)
    Applicable MaterialsPlastic granules and powders
    Output Units% retained by weight per sieve fraction
    Measured OutputsParticle size distribution, percent fines, percent oversize
    • Calibrated wire-cloth test sieves
    • Mechanical sieve shaker
    • Analytical balance
    • Drying oven
    • Sample splitter/divider
    • Data recording software

    Equipment and Instrumentation Used for ASTM D1921 Testing

    What You Receive: Test Report, Data, and Certification

    • Particle size distribution table and curve
    • Percent retained and percent passing values
    • Oversize and fines content data
    • Compliance reports
    • Comparative analysis against specification limits

    ASTM D1921 Plastic Material Particle Size Sieve Analysis FAQs

    ASTM D1921 determines particle size distribution of plastic materials using sieve analysis. It evaluates size range and uniformity, helping control processing behavior and ensure consistent performance in manufacturing operations.

    Key parameters include sieve size selection, sample mass, shaking time, and sieving method. Controlled conditions ensure accurate separation and measurement of particle size distribution in plastic materials.

    The test measures particle size distribution, typically reported as percentage retained on each sieve. Results indicate uniformity and grading of plastic materials for processing and quality control purposes.

    ASTM D1921 applies to plastic materials such as powders, granules, and pellets used in molding, extrusion, and compounding applications requiring controlled particle size distribution.

    ASTM D1921 may be affected by particle shape, agglomeration, and sieving efficiency. It may not accurately measure very fine particles, requiring additional analytical methods for detailed characterization.

    Why Choose Infinita Lab for Plastic Material Particle Size Sieve Analysis Testing?

    At the core of this breadth is our network of 2,000+ accredited laboratories across the USA, offering access to over 10,000 testing methods and analytical services. From advanced materials characterization (SEM, TEM, RBS, XPS) to mechanical, chemical, environmental, biological, and standardized ASTM/ISO-compliant testing, we deliver unmatched flexibility, specialization, and scale. You are never limited by geography, facility, or methodology — Infinita Lab connects you to the right expertise and testing solution, every time.

    brain

    Need ASTM D1921 Plastic Material Particle Size Sieve Analysis Testing You Can Rely On?

    Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / services / ASTM D1921: Plastic Material Particle Size Sieve Analysis Testing Services

    Discover more from Infinita Lab

    Subscribe now to keep reading and get access to the full archive.

    Continue reading

    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing