ASTM D1239: Plastic Film Chemical Extraction Testing Services

Accredited ASTM D1239 plastic film chemical extraction testing from Infinita Lab, performed to the exact standard requirements - accurate, reproducible results with full documentation for compliance, R&D, and quality control programs.

    Talk to an Expert
    ASTM D1239: Plastic Film Chemical Extraction Testing Services

    TRUSTED BY

    Get ASTM D1239 compliant results - request your plastic film chemical extraction testing quote

    • Overview
    • Scope, Applications, and Benefits
    • Test Process
    • Specifications
    • Instrumentation
    • Results and Deliverables

    What Is ASTM D1239 Plastic Film Chemical Extraction?

    ASTM D1239 determines the amount of extractable substances present in plastic films when exposed to specific solvents. The test evaluates chemical stability and the potential release of additives, plasticizers, or residual compounds.

    This method is widely used in packaging, food-contact materials, and polymer industries. It helps ensure material safety, compliance, and suitability for applications where chemical interaction is critical.

    Applications and Benefits of ASTM D1239 Plastic Film Chemical Extraction Testing

    Scope

    ASTM D1239 evaluates the chemical extractability of plastic films by exposing them to designated solvents under controlled conditions. The test measures the amount of material that can be extracted.

    The test evaluates:

    • Extractable content in plastic films
    • Chemical stability of polymer materials
    • Presence of additives or residual compounds
    • Suitability for sensitive applications
    • Compliance with regulatory requirements

    Applications

    • Food packaging films
    • Medical and pharmaceutical packaging
    • Flexible plastic films and sheets
    • Industrial polymer films
    • Consumer packaging materials
    • Quality control in film production

    Benefits

    • Ensures the chemical safety of materials
    • Detects residual or extractable substances
    • Supports regulatory compliance
    • Assists in material formulation improvement
    • Enables comparison of polymer performance

    Our ASTM D1239 Testing Procedure

    Sample Preparation

    Plastic film specimens are cut to specified size and weighed.

    1

    Solvent Exposure

    Samples are immersed in a selected solvent under controlled conditions.

    2

    Extraction Phase

    Extractable components dissolve into the solvent over time.

    3

    Data Recording & Evaluation

    Extracted material is measured to determine percentage extraction.

    4

    ASTM D1239 Test Parameters and Requirements

    ParameterDetails
    Applicable MaterialsPlastic films and sheets
    Solvent TypeWater, alcohol, or organic solvents
    Test Temperature~20°C to 60°C
    Exposure Time~1 hour to 24 hours
    Sample Thickness~0.01 mm to 1 mm
    Measured OutputsExtractables (% or mg/cm²)
    • Chemical-resistant containers
    • Temperature-controlled bath
    • Analytical balance (±0.001 g)
    • Drying oven
    • Solvent handling equipment
    • Data acquisition system

    Equipment and Instrumentation Used for ASTM D1239 Testing

    What You Receive: Test Report, Data, and Certification

    • Extractable content values (%)
    • Chemical stability assessment
    • Residual compound analysis
    • Material safety evaluation
    • Test condition summary
    • ASTM compliance report

    ASTM D1239 Plastic Film Chemical Extraction FAQs

    ASTM D1239 determines extractable components from plastic films using solvent extraction. It helps evaluate chemical residues, additives, and contaminants that may affect performance, safety, or compatibility in various applications.

    Key parameters include solvent type, extraction time, temperature, and sample thickness. Controlled conditions ensure consistent removal of extractable substances from plastic films for accurate analysis.

    The test measures amount of extractable material, typically reported as percentage or mass. Results indicate presence of additives, plasticizers, or impurities within the film.

    ASTM D1239 is used for plastic films such as polyethylene, polypropylene, and other polymer films used in packaging, medical, and industrial applications.

    ASTM D1239 depends on solvent selection and extraction conditions. Results may vary with method parameters and may not represent all possible extractable substances under different service environments.

    Why Choose Infinita Lab for Plastic Film Chemical Extraction Testing?

    When your Plastic Film Chemical Extraction results have to hold up - for compliance, a customer audit, or an engineering decision - ASTM D1239 accuracy and an unbiased third-party report matter more than price. Infinita Lab routes your ASTM D1239 plastic film chemical extraction testing to ISO/IEC 17025-accredited U.S. partner labs with hands-on method experience, so you get defensible data, transparent reporting, and turnaround times built around your project deadline - not ours.

    brain

    Need ASTM D1239 Plastic Film Chemical Extraction Testing You Can Rely On?

    Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / services / ASTM D1239: Plastic Film Chemical Extraction Testing Services

    Discover more from Infinita Lab

    Subscribe now to keep reading and get access to the full archive.

    Continue reading

    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing