ASTM D6110: Plastic Charpy Impact Testing Services

Accredited ASTM D6110 plastic charpy impact testing from Infinita Lab, performed to the exact standard requirements - accurate, reproducible results with full documentation for compliance, R&D, and quality control programs.

    Talk to an Expert
    ASTM D6110: Plastic Charpy Impact Testing Services

    TRUSTED BY

    Get ASTM D6110 compliant results - request your plastic charpy impact testing quote

    What Is ASTM D6110 Plastic Charpy Impact?

    ASTM D6110 describes a standard method for determining the Charpy impact resistance of notched plastic specimens. The high-strain-rate test results directly provide a measure of the energy absorbed by a material during fracture, i.e., toughness.

    A pendulum hammer strikes a notched specimen at a specified velocity; the energy absorbed at fracture is a measure of the material’s resistance to break under a shock force. ASTM D 6110 is widely used to assess the durability, resilience, and mechanical properties of plastic materials across a variety of applications.

    Applications and Benefits of ASTM D6110 Plastic Charpy Impact Testing

    Scope

    ASTM D6110 evaluates the impact resistance of plastic materials using notched specimens. It assesses:

    • Energy absorption during fracture
    • Ductile versus brittle fracture behaviour
    • Material toughness
    • Temperature-dependent fracture performance
    • Resistance to sudden mechanical shocks
    • Reliability of plastic components

    This method applies to rigid and semi-rigid plastic materials used in industrial and consumer applications.

    Applications

    • Automotive components (bumpers, dashboards, fuel systems)
    • Aerospace plastic parts
    • Consumer goods
    • Construction materials
    • Electrical enclosures
    • Packaging components
    • Research and development testing

    Benefits

    • Provides standardized impact resistance data
    • Supports informed material selection
    • Enhances product safety and durability
    • Enables comparison between plastic grades
    • Assists in quality control programs
    • Helps predict real-world performance

    Our ASTM D6110 Testing Procedure

    Specimen Preparation

    Standard specimens are prepared with precise dimensions and a machined notch.

    1

    Apparatus Setup & Impact Testing

    The specimen is mounted and struck by a pendulum hammer at a controlled velocity.

    2

    Energy Measurement & Correction

    Absorbed fracture energy is recorded and corrected for friction losses.

    3

    Data Normalization

    Results are normalized based on specimen dimensions.

    4

    ASTM D6110 Test Parameters and Requirements

    ParameterDetails
    Applicable MaterialsRigid and semi-rigid plastics
    Specimen Dimensions55 × 10 × 10 mm
    Notch TypeStandard V-notch
    Output UnitsJoules (J)
    Measured OutputsImpact energy, impact resistance
    • Charpy pendulum impact tester
    • Precision specimen holder
    • Calibrated energy scale
    • Notching machine
    • Temperature conditioning chamber (if required)
    • Data recording system

    Equipment and Instrumentation Used for ASTM D6110 Testing

    What You Receive: Test Report, Data, and Certification

    • Absorbed impact energy values (J)
    • Impact resistance calculations
    • Fracture mode classification (brittle/ductile)
    • Comparative material performance reports
    • Quality control documentation
    • Test certificates

    ASTM D6110 Plastic Charpy Impact FAQs

    ASTM D6110 determines the Charpy impact resistance of notched plastic specimens by measuring the energy absorbed when a standardized pendulum strikes and fractures the specimen. Results are reported as energy absorbed per unit specimen width.

    The milled notch creates a stress concentration that promotes fracture at a controlled location and reduces plastic deformation. This helps evaluate the material's resistance to impact under standardized conditions.

    ASTM D6110 is applicable to plastics that can be prepared as standardized specimens, including rigid and semi-rigid materials. The test can be used to compare impact performance of different plastic formulations, processing conditions, or material grades.

    Results can be significantly influenced by specimen fabrication and molding conditions, notch quality and preparation, specimen thickness and width, time between notching and testing, and environmental conditioning. Consistent specimen preparation and conditioning are therefore important for meaningful comparisons.

    ASTM D6110 provides useful data for evaluating impact resistance, material quality, formulation differences, and processing effects. The results are particularly useful for quality control, material specifications, research and development, and comparing plastics intended for applications subject to sudden or impact loading.

    ASTM D6110 determines the Charpy impact resistance of notched plastic specimens. A notched specimen is supported horizontally and struck by a pendulum hammer, which breaks it with a single swing. The energy absorbed during fracture is measured and reported relative to the specimen width to evaluate the material's resistance to impact.

    ASTM D6110 specimens typically measure 127 mm (5 in.) long and 12.7 mm (0.5 in.) deep, with the width varying according to the material specification. A standardized notch is machined into the specimen to concentrate stress and guide fracture. Exact dimensions, notch geometry, and specimen width must be verified against the applicable edition of ASTM D6110 and the material requirements.

    Why Choose Infinita Lab for Plastic Charpy Impact Testing

    When your Plastic Charpy Impact results have to hold up - for compliance, a customer audit, or an engineering decision - ASTM D6110 accuracy and an unbiased third-party report matter more than price. Infinita Lab routes your ASTM D6110 plastic charpy impact testing to ISO/IEC 17025-accredited U.S. partner labs with hands-on method experience, so you get defensible data, transparent reporting, and turnaround times built around your project deadline - not ours.

    brain

    Need ASTM D6110 Plastic Charpy Impact Testing You Can Rely On?

    Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / services / ASTM D6110: Plastic Charpy Impact Testing Services
    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing