Scope:

The torque strength of ultraviolet light-cured glass or metal adhesive joints is determined using the ASTM D3685 test procedure. This test method can be used to compare torque strength-to-failure data for different bonded joint systems, whether or not they are radiation cured. This test procedure yields reasonably accurate results in terms of the UV curing adhesives’ capacity to endure torsional shearing pressures. This test method can also be used to see how the environment affects torsional shear strength.

Manual assembly practices are also appropriate for UV curable adhesives. Because the glass/metal will not cure until it is exposed to light, users can make fine alignment modifications before joining.

Test procedure:

Standard bonded specimens are produced, irradiated, loaded, and tested under defined conditions for the ASTM D3685 test process. The specimens are placed in the holding fixture, making sure that there is no lateral movement. Then, mechanically or with the aid of a constant drive loader, a torque is applied to the hex nut assembly at a rate of 0.5 rpm until failure occurs. The load at failure, as well as the nature and extent of the failure, are all noted.

Specimen size:

UV bonded hexagonal metal blocks and glass plates are used as test specimens for the ASTM D3685 test procedure.

Data:

As per the ASTM D3685 test method, all failure loads are expressed in lbf·in. (or N·m).

Conclusion:

The torque strength of ultraviolet light-cured glass or metal adhesive joints is determined using the ASTM D3685 test procedure.


3 Easy Steps
to Start Testing

  • Share Your Testing Material Details with Us
  • Hassle-Free Collection Pick-Up Service
  • We Find the Lab, You Get the Results
Arrow

Error: Contact form not found.

Case Studies

In-depth examination of genuine material testing solutions

Case Study: Dopant & Ultra-Low Concentration Analysis via…

Infinita Engineering Visual showing Case Study Dopant microscopy / imaging workflow for case study: dopant & ultra-low concentration analysis via stem-eels.

Case Study: Dopant & Ultra-Low Concentration Analysis via…

Introduction to STEM-EELS for Elemental Analysis Scanning Transmission Electron Microscopy (STEM) combined with Electron Energy Loss...

Read Case Study

AFM Silicon Wafer Nano Roughness Measurement Guide Testing…

Infinita Engineering Visual showing Afm Nano Scale general testing / industry guide workflow for afm nano-scale roughness measurement guide for silicon wafers.

AFM Silicon Wafer Nano Roughness Measurement Guide Testing…

Nano-scale surface roughness is a critical parameter in fabricated thin-films that are used in optics, solar...

Read Case Study

Talk to Our Experts Today!

Submit your contact info and we’ll get back to you within 24 hours

    Home / Blog / ASTM D3658: Torque Strength of UV-Cured Glass-Metal Adhesive Joints

    Discover more from Infinita Lab

    Subscribe now to keep reading and get access to the full archive.

    Continue reading

    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing