Use this checklist before you submit a Class II 510(k).
Most Additional Information (AI) holds trace to a single testing gap — a missing biocompatibility endpoint, an EMC report against a superseded edition, or a shelf-life claim without defensible aging data. Surfacing those gaps before you submit is far cheaper than discovering them mid-review.
Why it matters
A gap found in review costs weeks; the same gap found here costs a scoping call.
The checklist
- Map every requirement in your V&V plan to a planned test and an acceptance criterion.
- Confirm the biocompatibility plan reflects a risk-based ISO 10993-1:2018 rationale rather than a fixed animal-test matrix.
- Scope chemical characterization (ISO 10993-18) where a risk-based rationale calls for it.
- Verify electrical safety and EMC are run against the current IEC 60601-1/-1-2 editions.
- Check sterile-packaging validation (ISO 11607) and accelerated aging (ASTM F1980) protocols are defensible.
- Confirm every report is ISO 17025-accredited with traceable methods.
- Ensure sample sizes and pass/fail logic map to your acceptance criteria.
- Use the predicate comparison to identify exactly which gaps need new data.
How to use it
Work through it with your regulatory lead before you lock the submission. Any item you can’t check confidently is a candidate for testing now, not an AI response later. Infinita Lab can scope only the gaps your predicate and prior data don’t already cover.
How Infinita Lab helps
Infinita Lab works as your single point of contact across a network of 2,000+ accredited U.S. laboratories and more than 20,000 test types. Every project is owned end-to-end by a master’s-level scientist or engineer — not a coordinator — covering scope definition, lab selection, sample logistics, results interpretation and reporting. All testing is performed under ISO 17025 accreditation with traceable methods, and confidentiality is standard: anonymized lab relationships and NDAs protect your program at every step.
How engagement works
Engagement is straightforward: we scope the testing with you, select the right accredited lab from the network, coordinate sample logistics, run the work, interpret the results and deliver a traceable report — all through one point of contact, so you never chase multiple vendors or reconcile mismatched quotes. When timelines are tight, workstreams run in parallel to keep testing off your critical path.
Accreditation & turnaround
All testing is performed under ISO 17025 accreditation with traceable methods and documented chain of custody, so results stand up in a submission, an audit or a dispute. Turnaround is scoped to your deadline rather than a lab queue, and when timelines are tight, workstreams run in parallel to protect your schedule. You always know where your samples are and when data is due.
Confidentiality
Confidentiality is standard on every engagement. Infinita Lab works through anonymized lab relationships and mutual NDAs, so your product design, formulation, test data and program details stay protected from first contact through the final report. Nothing about your project is shared, referenced or reused without your agreement.