    What Is ASTM D2842 Rigid Foam Water Absorption?

    ASTM D2842 describes a standardised method for determining the water absorption of rigid cellular plastics (rigid foam). Water absorption is an important property for foam insulation and structural foam applications because absorbed moisture increases thermal conductivity, reduces mechanical strength, and can promote long-term dimensional instability.

    The test involves immersing a precisely measured rigid foam specimen in distilled water at a specified depth and temperature for a defined period. After immersion, the specimen is removed, surface-dried, and reweighed. Water absorption is calculated as the volume of water absorbed per unit of specimen surface area, or as a percentage of specimen volume. This data allows designers and specifiers to assess the foam’s suitability for wet or humid service environments.

    Applications and Benefits of ASTM D2842 Rigid Foam Water Absorption Testing

    Scope

    ASTM D2842 evaluates:

    • Volume of water absorbed per unit area of rigid cellular plastics
    • Percent water absorption by volume
    • Open-cell content influence on water uptake
    • Effect of immersion depth and temperature on absorption
    • Long-term moisture resistance of foam insulation
    • Comparative water absorption across foam types and densities

    Applications

    • Building and construction insulation boards
    • Cold storage and refrigeration panel cores
    • Roofing system insulation
    • Below-grade foundation insulation
    • Marine and offshore foam applications
    • Pipe and equipment insulation
    • Sandwich panel core materials

    Benefits

    • Predicts moisture resistance in wet service environments
    • Supports material selection for below-grade or marine use
    • Provides data for thermal performance modeling
    • Enables compliance with building code moisture requirements
    • Identifies foam formulations with excessive open-cell content
    • Reduces long-term insulation degradation risk

    Our ASTM D2842 Testing Procedure

    Specimen Preparation

    Rigid foam specimens are cut to specified dimensions, measured, and weighed.

    1

    Immersion

    Specimens are submerged at the specified depth in distilled water at the test temperature.

    2

    Duration

    Specimens remain immersed for the required test period (typically 96 hours).

    3

    Post-Immersion Measurement

    Specimens are removed, surface water is blotted, and specimens are reweighed immediately.

    4

    ASTM D2842 Test Parameters and Requirements

    ParameterDetails
    Applicable MaterialsRigid cellular plastics / rigid foam materials
    Specimen TypesCut foam specimens, typically rectangular blocks or sheets
    Immersion Condition5.1 cm (2 in.) water head
    Standard Test Duration96 hours
    Test EnvironmentControlled ambient laboratory conditions
    • Water immersion tank with temperature control
    • Analytical balance
    • Digital calipers for specimen dimensioning
    • Blotting paper or absorbent cloth
    • Timer
    • Data recording system

    Equipment and Instrumentation Used for ASTM D2842 Testing

    What You Receive: Test Report, Data, and Certification

    • Water absorption volume per unit area
    • Percent water absorption by volume
    • Pre- and post-immersion mass records
    • Specimen dimensional data
    • Quality assurance reports

    ASTM D2842 Rigid Foam Water Absorption FAQs

    It measures the amount of water absorbed by rigid cellular plastics after immersion for a specified time period.

    The standard immersion period is 96 hours, unless otherwise agreed between the manufacturer and purchaser.

    This test is commonly used for rigid foam insulation boards, polyurethane foams, polystyrene foams, and other cellular plastics.

    It helps evaluate moisture resistance, dimensional stability, and insulation performance of foam materials in service.

    It is widely used in construction, insulation, packaging, automotive, and polymer manufacturing industries.

    ASTM D2842 measures the water absorption of rigid cellular plastics by immersing specimens in water, typically for 96 hours, and measuring changes in buoyant force. The results help evaluate moisture resistance and compare materials for insulation and other applications.

    ASTM D570 measures the rate and amount of water absorbed by plastics during immersion. Specimens are weighed before and after exposure to water, and the change in mass is used to calculate water absorption. The results help assess moisture effects on a plastic’s dimensions, appearance, and mechanical or electrical properties.

    Why Choose Infinita Lab for Rigid Foam Water Absorption Testing?

    When your Rigid Foam Water Absorption results have to hold up - for compliance, a customer audit, or an engineering decision - ASTM D2842 accuracy and an unbiased third-party report matter more than price. Infinita Lab routes your ASTM D2842 rigid foam water absorption testing to ISO/IEC 17025-accredited U.S. partner labs with hands-on method experience, so you get defensible data, transparent reporting, and turnaround times built around your project deadline - not ours.

    brain

    Need ASTM D2842 Rigid Foam Water Absorption Testing You Can Rely On?

    Send query us at hello@infinitalab.com or call us at (888) 878-3090 to learn more about our services and how we can support you.

     Request a Quote

    Request a Quote

    Submit your material details and receive testing procedures, pricing, and turnaround time within 24 hours.



    • ddd
      Quick Turnaround and Hasslefree process
    • ddd
      Confidentiality Guarantee
    • ddd
      Free, No-obligation Consultation
    • ddd
      100% Customer Satisfaction
    Home / services / ASTM D2842: Rigid Foam Water Absorption Testing Services
    ×

    Talk to an Expert

      Connect Instantly

      (888) 878-3090
      Ensure Quality with the Widest Network of Accredited Labs
      • ddd
        Quick Turnaround and Hasslefree process
      • ddd
        Confidentiality Guarantee
      • ddd
        Free, No-obligation Consultation
      • ddd
        100% Customer Satisfaction

        ddd

        Start Material Testing