(888) 878-3090
An effective analytical method for performing extremely accurate and typically non-destructive elemental analyses on a variety of materials is X-ray fluorescence (XRF) spectrometry. Numerous elemental analysis applications, including those in electronics, plastics, rubbers, geology, forensics, and WEEE / RoHS / ELV compliance testing, can be carried out using XRF.
X-ray Fluorescence Spectrometry (XRF)
An energy dispersive x-ray fluorescence (EDXRF) spectrometer is the XRF device used at Infinita Labs. Nearly every element in the periodic table, from sodium (Na) to uranium (U), can be measured using the EDXRF in concentrations ranging from ppm levels to about 100% by weight. It can be applied to the addition of small additives as well as the monitoring of significant components in a process or product.
The EDXRF’s minimal sample preparation requirements and ability to perform quick, real-time multi-element analyses on a variety of samples, including solids, liquids, powders, thin films, slurries, and pastes, are two of its most crucial features. These benefits approach appealing to a wide range of sectors.
Additionally, the EDXRF at Infinita Labs can carry out high-precision analysis on a 0.1 mm or 1.2 mm in diameter area. It is compatible with a wide range of sample sizes, from small parts to massive goods, thanks to the combination of its large sample chamber and small X-ray beam diameter. Without sample preparation, the elemental content of products and parts can be measured.
Variety of X-ray services with pride:
Applications for these services are numerous and diversifying daily. Although the Latest X-ray systems and services have their roots in electronics in general and printed circuit boards in particular, they are now used for a variety of applications including metrology, mechanical engineering, counterfeit screening, additive 3D printing and manufacturing, injection moulding, casting, materials science, biotechnology, medical, and aerospace. Every year, there are more applications on the list. Every week, we take on a wider range of projects. We welcome what we affectionately refer to as “scientific projects,” which are merely new applications to our group. We encourage potential clients with similar projects to get in touch with us, explain their difficulties, and bring us a sample part for inspection. We will give you our time in return if you give it to us. If your application can be successfully addressed, we’ll come up with a mutually agreeable inspection schedule. If we are unsuccessful, we will shake hands, not bill you for the effort, and hope to work with you more successfully in the future.
Every solder joint on a printed circuit board is captured in 3D laminographic images using Automatic X-ray Inspection, or AXI, from both the top and bottom sides. A program that examines newly manufactured failed, and “bone pile” boards against preloaded algorithms that inspect solder joints by IPC-A-610 requirements is based on ODB++ or Ascii-formatted CAD files. Failures are located, and photographs of flaws are taken and recorded. Suitable for manufacturing in low- to high-volume.
Top-down and oblique angle views of geometric objects are used in 2D and 3D X-ray inspection services to spot known flaws or confirm specific traits, qualities, or screen irregularities in materials. The emphasis is on quickly validating suspicions with results. Most tasks can be finished within 1-3 working days. This is significant since our main client is a process or quality engineer who has an urgent problem that needs to be fixed. Reports can come after, but getting a visual of the issue is crucial so that quick corrective action can be performed.
Services for digital radiography (DR) Services for nondestructive testing (NDT) for materials analysis, process validation, and defect detection.
Industrial CT scanning services 3D tomographic imaging and analysis for metrology applications, materials analysis, and process validation as well as nondestructive testing (NDT) of difficult-to-identify flaws. Class II and Class III technicians that have received NAS 410 certification are available for projects.
Video 01:X-ray inspection system “All in one”
hello@infinitalab.com
Enter Sample and testing requirementsProvide your contact information
Attach file
Δ
EELS analysis of gate and channel is performed on fin field-effect transistors (finFETs). Scanning transmission electron…
FTIR analysis is used to study the migration and leaching of phthalate plasticizers from p-PVCs. Phthalate…
Nano-scale surface roughness is a critical parameter in fabricated thin-films that are used in optics, solar…
Start Testing
ASTM E572 test method covers the analysis of stainless and alloy steels by Wavelength Dispersive X-ray Fluorescence Spectrometry (WDXRF). It provides rapid, multi-element determinations with sufficient accuracy to assure product quality.
The ASTM D2674 test is a standard test method for the analysis of sulfochromate etch solutions used in the surface preparation of aluminum. The ASTM D2674 standard specifies a method for determining the efficacy of an etchant used to prepare the surface of aluminum alloys for subsequent adhesive bonding.
An immunological method for quantization of Hevea Natural Rubber (HNRL) proteins using rabbit anti-HNRL serum. Rabbits immunized with HNRL proteins react to the majority of the proteins present, and their sera have the capability to detect most if not all the proteins in HNRL.
ASTM G65 measures the resistance of metallic materials to abrasion using the dry sand/rubber wheel apparatus. The quality, durability, and toughness of the sample are determined using this test. Metallic materials are ranked in their resistance to scratching abrasion under a controlled environment.
ASTM E2141 test methods provide accelerated aging and monitoring of the performance of time-dependent electrochromic devices (ECD) integrated in insulating glass units (IGU). This test helps to understand the relative serviceability of electrochromic glazings applied on ECD.
ASTM C724 test method is used in analyzing the quality and ease of maintenance of a ceramic decoration on architectural-type glass. This test method is useful in the acknowledgment of technical standards.
You share material and testing requirements with us
You ship your sample to us or arrange for us to pick it up.
We deliver the test report to your email.
Let’s work together!
Share your testing requirements with us and we will be happy to assist you.
What Material or product do you have?
What analysis do you need?
How many parts or coupons do you have?
How fast do you need the results back?
Do you know the goal of the analysis you need?
Contact Information
Name
E-mail
Contact number
Query
Submit